DigiNepal Health ENनेहि

Imaging & scans A–Z

X-ray, ultrasound, CT and MRI explained — why, preparation and safety.

General health information, not a diagnosis. In an emergency, call 102. Always consult a qualified health professional.

Abdominal MRI (liver, pancreas, kidneys)
A Abdominal MRI (liver, pancreas, kidneys) is a mri test of the abdomen. It shows liver lesions (LI-RADS), pancreas, kidney masses. No ionising radiation (magnetic field and radio waves).
Abdominal ultrasound
A safe scan using sound waves to look inside the abdomen.
Abdominal X-ray
A Abdominal X-ray is a x-ray test of the abdomen. It shows bowel gas pattern, obstruction, some kidney stones, swallowed objects. Typical effective dose 0.4 to 0.7 mSv, similar to about 2 to 3 months of natural background radiation (about 3 mSv a year).
Ambulatory blood pressure monitoring (ABPM)
A Ambulatory blood pressure monitoring (ABPM) is a diagnostic procedure test of the circulation. It shows blood pressure over 24 hours, including at night. No ionising radiation when done without X-ray guidance.
Ankle MRI
A Ankle MRI is a mri test of the ankle. It shows ligaments, tendons, cartilage. No ionising radiation (magnetic field and radio waves).
Ankle-brachial index (ABI)
A Ankle-brachial index (ABI) is a diagnostic procedure test of the leg arteries. It shows compares ankle and arm blood pressure to detect narrowed leg arteries. No ionising radiation when done without X-ray guidance.
Anomaly scan (second-trimester scan)
A Anomaly scan (second-trimester scan) is a ultrasound test of the pregnancy. It shows baby's organs and structure at 18 to 22 weeks, placenta position. No ionising radiation (sound waves).
Arterial Doppler of the legs
A Arterial Doppler of the legs is a ultrasound test of the leg arteries. It shows narrowed or blocked arteries. No ionising radiation (sound waves).
Audiometry (hearing test)
A Audiometry (hearing test) is a diagnostic procedure test of the ears. It shows hearing level at different pitches. No ionising radiation when done without X-ray guidance.
Barium enema
A Barium enema is a fluoroscopy test of the large bowel. It shows large bowel shape; largely replaced by colonoscopy or CT colonography. Typical effective dose 5 to 8 mSv, similar to about 2 to 3 years of natural background radiation (about 3 mSv a year).
Barium meal and follow-through
A Barium meal and follow-through is a fluoroscopy test of the stomach and small bowel. It shows stomach and small bowel shape and passage. Typical effective dose 2 to 3 mSv, similar to about 8 months to 1 year of natural background radiation (about 3 mSv a year).
Barium swallow
A Barium swallow is a fluoroscopy test of the oesophagus. It shows swallowing problems, narrowing, hernia. Typical effective dose 1 to 2 mSv, similar to about 4 to 8 months of natural background radiation (about 3 mSv a year).
Bladder scan (post-void residual)
A Bladder scan (post-void residual) is a ultrasound test of the bladder. It shows urine left after passing urine. No ionising radiation (sound waves).
Bone density scan (DEXA)
A Bone density scan (DEXA) is a x-ray (low dose) test of the hip and spine. It shows bone density as T-score; osteoporosis. Typical effective dose about 0.001 mSv, similar to less than a day of natural background radiation (about 3 mSv a year).
Bone marrow aspiration and biopsy
A Bone marrow aspiration and biopsy is a diagnostic procedure test of the hip bone. It shows blood-forming cells in the marrow. No ionising radiation when done without X-ray guidance.
Bone scan (bone scintigraphy)
A Bone scan (bone scintigraphy) is a nuclear medicine test of the whole skeleton. It shows areas of increased bone activity: cancer spread, infection, stress fractures. Typical effective dose 3 to 6 mSv, similar to about 1 to 2 years of natural background radiation (about 3 mSv a year).
Brachial plexus MRI
A Brachial plexus MRI is a mri test of the neck and shoulder nerves. It shows nerve injuries and compression. No ionising radiation (magnetic field and radio waves).
Breast MRI
A Breast MRI is a mri test of the breast. It shows breast cancer extent, high-risk screening, implants. No ionising radiation (magnetic field and radio waves).
Breast tomosynthesis (3D mammography)
A Breast tomosynthesis (3D mammography) is a mammography test of the breast. It shows layered images that reduce overlapping tissue; reported with BI-RADS. Typical effective dose 0.5 to 0.6 mSv, similar to about 2 months of natural background radiation (about 3 mSv a year).
Breast ultrasound
A Breast ultrasound is a ultrasound test of the breast. It shows lumps (solid or cyst), abscess; reported with BI-RADS. No ionising radiation (sound waves).
Bronchoscopy
A Bronchoscopy is a diagnostic procedure test of the airways. It shows inside the airways; samples for TB, infection or cancer. No ionising radiation when done without X-ray guidance.
Bubble (contrast) echocardiogram
A Bubble (contrast) echocardiogram is a ultrasound test of the heart. It shows a small hole between heart chambers (PFO) using agitated saline. No ionising radiation (sound waves).
Capsule endoscopy
A Capsule endoscopy is a diagnostic procedure test of the small bowel. It shows pictures of the small bowel from a swallowed camera. No ionising radiation when done without X-ray guidance.
Cardiac MRI
A Cardiac MRI is a mri test of the heart. It shows heart muscle, scarring, inflammation, pumping. No ionising radiation (magnetic field and radio waves).
Cardiotocography (CTG, NST)
A Cardiotocography (CTG, NST) is a diagnostic procedure test of the pregnancy. It shows baby's heart rate and the mother's contractions. No ionising radiation when done without X-ray guidance.
Carotid Doppler
A Carotid Doppler is a ultrasound test of the neck arteries. It shows narrowing of the arteries to the brain. No ionising radiation (sound waves).
Catheter angiography
A Catheter angiography is a interventional test of the blood vessels. It shows detailed vessel pictures through a catheter; treatment can be done at the same time. Typical effective dose 5 to 15 mSv, similar to about 2 to 5 years of natural background radiation (about 3 mSv a year).
Chest ultrasound
A Chest ultrasound is a ultrasound test of the chest. It shows fluid around the lung, guides drainage. No ionising radiation (sound waves).
Chest X-ray
A Chest X-ray is a x-ray test of the chest. It shows lungs, heart size, ribs; pneumonia, TB, fluid, collapsed lung. Typical effective dose 0.02 to 0.1 mSv, similar to about 3 to 10 days of natural background radiation (about 3 mSv a year).
Chest X-ray
A quick X-ray picture of the lungs, heart and chest.
Chest X-ray in children
A Chest X-ray in children is a x-ray test of the chest. It shows pneumonia, inhaled objects, heart size. Typical effective dose 0.01 to 0.02 mSv, similar to a few days of natural background radiation (about 3 mSv a year).
Chest X-ray, lateral view
A Chest X-ray, lateral view is a x-ray test of the chest. It shows areas hidden on the front view, small effusions. Typical effective dose 0.04 to 0.1 mSv, similar to about 1 to 2 weeks of natural background radiation (about 3 mSv a year).
Collarbone (clavicle) X-ray
A Collarbone (clavicle) X-ray is a x-ray test of the collarbone. It shows collarbone fractures and joint injuries. Typical effective dose 0.01 mSv, similar to about 1 day of natural background radiation (about 3 mSv a year).
Colonoscopy
A Colonoscopy is a diagnostic procedure test of the large bowel. It shows polyps, cancer, inflammation, bleeding sources; polyps can be removed. No ionising radiation when done without X-ray guidance.
Colposcopy
A Colposcopy is a diagnostic procedure test of the cervix. It shows magnified view of the cervix with biopsy if needed. No ionising radiation when done without X-ray guidance.
Contrast CT of the brain
A Contrast CT of the brain is a ct test of the head. It shows tumours, abscesses, infections such as neurocysticercosis. Typical effective dose 2 to 4 mSv, similar to about 8 months to 1.5 years of natural background radiation (about 3 mSv a year).
Coronary angiography
A Coronary angiography is a interventional test of the heart arteries. It shows blockages in the heart arteries; stenting (angioplasty) may follow. Typical effective dose 5 to 10 mSv, similar to about 2 to 3 years of natural background radiation (about 3 mSv a year).
Coronary calcium score CT
A Coronary calcium score CT is a ct test of the heart arteries. It shows calcium in the heart arteries, a marker of heart risk. Typical effective dose 1 to 3 mSv, similar to about 4 months to 1 year of natural background radiation (about 3 mSv a year).
Cranial ultrasound in babies
A Cranial ultrasound in babies is a ultrasound test of the head (infant). It shows brain of newborns through the soft spot: bleeding, fluid. No ionising radiation (sound waves).
CT angiography of the head and neck
A CT angiography of the head and neck is a ct test of the head and neck vessels. It shows blocked or burst vessels, aneurysms. Typical effective dose 3 to 5 mSv, similar to about 1 to 2 years of natural background radiation (about 3 mSv a year).
CT aortogram
A CT aortogram is a ct test of the aorta. It shows aortic aneurysm or dissection. Typical effective dose 10 to 20 mSv, similar to about 3 to 7 years of natural background radiation (about 3 mSv a year).
CT colonography (virtual colonoscopy)
A CT colonography (virtual colonoscopy) is a ct test of the large bowel. It shows polyps and cancers of the colon. Typical effective dose 5 to 8 mSv, similar to about 2 to 3 years of natural background radiation (about 3 mSv a year).
CT coronary angiography (CTCA)
A CT coronary angiography (CTCA) is a ct test of the heart arteries. It shows narrowing in the heart arteries. Typical effective dose 2 to 12 mSv, similar to about 8 months to 4 years of natural background radiation (about 3 mSv a year).
CT enterography
A CT enterography is a ct test of the small bowel. It shows small bowel inflammation (for example Crohn's disease, intestinal TB). Typical effective dose 6 to 10 mSv, similar to about 2 to 3 years of natural background radiation (about 3 mSv a year).
CT for heart valve planning (TAVI CT)
A CT for heart valve planning (TAVI CT) is a ct test of the heart and vessels. It shows measurements for transcatheter valve replacement. Typical effective dose 5 to 15 mSv, similar to about 2 to 5 years of natural background radiation (about 3 mSv a year).
CT KUB (stone protocol)
A CT KUB (stone protocol) is a ct test of the kidneys, ureters and bladder. It shows kidney and ureter stones, without contrast. Typical effective dose 2 to 5 (low dose) mSv, similar to about 8 months to 1.5 years of natural background radiation (about 3 mSv a year).
CT myelogram
A CT myelogram is a fluoroscopy test of the spine. It shows nerve root and cord compression when MRI is not possible. Typical effective dose 3 to 10 mSv, similar to about 1 to 3 years of natural background radiation (about 3 mSv a year).
CT perfusion of the brain
A CT perfusion of the brain is a ct test of the head. It shows brain tissue at risk during a stroke. Typical effective dose 2 to 5 mSv, similar to about 8 months to 1.5 years of natural background radiation (about 3 mSv a year).
CT peripheral angiography
A CT peripheral angiography is a ct test of the leg arteries. It shows blocked leg arteries. Typical effective dose 5 to 10 mSv, similar to about 2 to 3 years of natural background radiation (about 3 mSv a year).
CT pulmonary angiography (CTPA)
A CT pulmonary angiography (CTPA) is a ct test of the chest vessels. It shows clots in the lung arteries (pulmonary embolism). Typical effective dose 4 to 10 mSv, similar to about 1.5 to 3 years of natural background radiation (about 3 mSv a year).
CT scan of the abdomen and pelvis
A CT scan of the abdomen and pelvis is a ct test of the abdomen and pelvis. It shows organs, stones (CT KUB), appendicitis, masses, liver lesions (LI-RADS). Typical effective dose 8 to 10 mSv, similar to about 3 years of natural background radiation (about 3 mSv a year).
CT scan of the chest
A CT scan of the chest is a ct test of the chest. It shows lungs in detail: infections, nodules (Lung-RADS), masses, interstitial disease. Typical effective dose 1.5 to 7 (low-dose screening about 1.5) mSv, similar to about 6 months to 2 years of natural background radiation (about 3 mSv a year).
CT scan of the head
A CT scan of the head is a ct test of the head. It shows bleeding, stroke, fractures, swelling, tumours. Typical effective dose 1 to 2 mSv, similar to about 4 to 8 months of natural background radiation (about 3 mSv a year).
CT scan of the head
A detailed X-ray scan of the brain, often used in emergencies.
CT scan of the neck
A CT scan of the neck is a ct test of the neck. It shows lumps, abscesses, cancers of the throat and voice box. Typical effective dose 2 to 3 mSv, similar to about 1 year of natural background radiation (about 3 mSv a year).
CT scan of the orbits
A CT scan of the orbits is a ct test of the eyes. It shows orbital fractures, infection, foreign bodies. Typical effective dose 0.5 to 1 mSv, similar to about 2 to 4 months of natural background radiation (about 3 mSv a year).
CT scan of the pelvis
A CT scan of the pelvis is a ct test of the pelvis. It shows pelvic fractures, masses. Typical effective dose 3 to 6 mSv, similar to about 1 to 2 years of natural background radiation (about 3 mSv a year).
CT scan of the sinuses (CT PNS)
A CT scan of the sinuses (CT PNS) is a ct test of the face. It shows sinus blockage, polyps, anatomy before surgery. Typical effective dose 0.5 to 1 mSv, similar to about 2 to 4 months of natural background radiation (about 3 mSv a year).
CT scan of the spine
A CT scan of the spine is a ct test of the spine. It shows fractures and bone detail. Typical effective dose 4 to 10 mSv, similar to about 1.5 to 3 years of natural background radiation (about 3 mSv a year).
CT scan radiation dose
Typical CT doses compared with background radiation.
CT temporal bone (HRCT ear)
A CT temporal bone (HRCT ear) is a ct test of the ear. It shows middle and inner ear bone detail, cholesteatoma. Typical effective dose 1 to 2 mSv, similar to about 4 to 8 months of natural background radiation (about 3 mSv a year).
CT urography
A CT urography is a ct test of the urinary tract. It shows kidneys, ureters and bladder with contrast. Typical effective dose 10 to 15 mSv, similar to about 3 to 5 years of natural background radiation (about 3 mSv a year).
CT-guided biopsy
A CT-guided biopsy is a ct test of the variable. It shows takes a tissue sample from a lump using CT to guide the needle. Typical effective dose 2 to 10 mSv, similar to about 8 months to 3 years of natural background radiation (about 3 mSv a year).
Cystoscopy
A Cystoscopy is a diagnostic procedure test of the bladder. It shows inside the bladder and urethra. No ionising radiation when done without X-ray guidance.
Dacryocystogram
A Dacryocystogram is a fluoroscopy test of the tear ducts. It shows blocked tear ducts. Typical effective dose 0.1 to 0.5 mSv, similar to about 2 weeks to 2 months of natural background radiation (about 3 mSv a year).
Defecography
A Defecography is a fluoroscopy test of the rectum. It shows rectal emptying and pelvic floor movement. Typical effective dose 1 to 3 (fluoroscopy) or none (MRI) mSv, similar to up to about 1 year of natural background radiation (about 3 mSv a year).
Dental panoramic X-ray (OPG)
A Dental panoramic X-ray (OPG) is a x-ray test of the teeth and jaw. It shows all teeth, roots, jaws, impacted wisdom teeth. Typical effective dose 0.01 to 0.02 mSv, similar to about 1 to 3 days of natural background radiation (about 3 mSv a year).
DEXA body composition
A DEXA body composition is a dexa test of the whole body. It shows fat, muscle and bone amounts. Typical effective dose about 0.001 to 0.01 mSv, similar to under a day of natural background radiation (about 3 mSv a year).
Dialysis access imaging and procedures (fistulogram, catheter)
A Dialysis access imaging and procedures (fistulogram, catheter) is a interventional test of the arm or neck vessels. It shows checks or creates access for dialysis. Typical effective dose 0.5 to 5 mSv, similar to up to about 1.5 years of natural background radiation (about 3 mSv a year).
DMSA renal scan
A DMSA renal scan is a nuclear medicine test of the kidneys. It shows kidney scarring and split function. Typical effective dose 0.7 to 1 mSv, similar to about 3 to 4 months of natural background radiation (about 3 mSv a year).
Doppler ultrasound
A Doppler ultrasound is a ultrasound test of the blood vessels. It shows blood flow, clots in leg veins (DVT), narrowed arteries. No ionising radiation (sound waves).
DTPA / MAG3 renogram
A DTPA / MAG3 renogram is a nuclear medicine test of the kidneys. It shows kidney function and drainage, blockage. Typical effective dose 1 to 2 mSv, similar to about 4 to 8 months of natural background radiation (about 3 mSv a year).
ECG (heart tracing)
A quick, painless recording of the heart's electrical activity.
Echocardiogram (echo)
A Echocardiogram (echo) is a ultrasound test of the heart. It shows heart pumping (ejection fraction), valves, chambers, fluid. No ionising radiation (sound waves).
Elbow X-ray
A Elbow X-ray is a x-ray test of the elbow. It shows fractures and dislocations, common in children's falls. Typical effective dose 0.001 mSv, similar to under a day of natural background radiation (about 3 mSv a year).
Electrocardiogram (ECG)
A Electrocardiogram (ECG) is a ecg test of the heart. It shows heart rhythm and electrical activity: heart attack, atrial fibrillation, strain. No ionising radiation (electrical recording).
Electroencephalogram (EEG)
A Electroencephalogram (EEG) is a diagnostic procedure test of the brain. It shows electrical activity of the brain. No ionising radiation when done without X-ray guidance.
Endoscopic ultrasound (EUS)
A Endoscopic ultrasound (EUS) is a diagnostic procedure test of the pancreas, bile ducts, gut wall. It shows detailed ultrasound from inside the gut; can take samples. No ionising radiation when done without X-ray guidance.
ERCP (endoscopic retrograde cholangiopancreatography)
A ERCP (endoscopic retrograde cholangiopancreatography) is a interventional test of the bile ducts and pancreas. It shows endoscope plus X-ray to see and treat bile duct stones or narrowing. Typical effective dose 2 to 6 mSv, similar to about 8 months to 2 years of natural background radiation (about 3 mSv a year).
Eye (ocular) ultrasound
A Eye (ocular) ultrasound is a ultrasound test of the eye. It shows retinal detachment, bleeding inside the eye when the view is blocked. No ionising radiation (sound waves).
Fetal echocardiography
A Fetal echocardiography is a ultrasound test of the pregnancy (baby's heart). It shows baby's heart structure. No ionising radiation (sound waves).
Fetal MRI
A Fetal MRI is a mri test of the pregnancy. It shows detailed fetal anatomy when ultrasound is unclear. No ionising radiation (magnetic field and radio waves).
First-trimester (early pregnancy) scan
A First-trimester (early pregnancy) scan is a ultrasound test of the pregnancy. It shows pregnancy location, heartbeat, number of babies, due date. No ionising radiation (sound waves).
Fistulogram / sinogram
A Fistulogram / sinogram is a fluoroscopy test of the variable. It shows the path of an abnormal tract or sinus. Typical effective dose 0.5 to 2 mSv, similar to about 2 to 8 months of natural background radiation (about 3 mSv a year).
Flexible sigmoidoscopy
A Flexible sigmoidoscopy is a diagnostic procedure test of the lower large bowel. It shows the rectum and lower colon. No ionising radiation when done without X-ray guidance.
Follicular monitoring (ovulation scans)
A Follicular monitoring (ovulation scans) is a ultrasound test of the ovaries. It shows egg follicle growth and ovulation. No ionising radiation (sound waves).
Foot and ankle X-ray
A Foot and ankle X-ray is a x-ray test of the foot and ankle. It shows fractures, arthritis, gout erosions, foreign bodies. Typical effective dose 0.001 mSv, similar to under a day of natural background radiation (about 3 mSv a year).
Forearm X-ray
A Forearm X-ray is a x-ray test of the forearm. It shows fractures of the radius and ulna. Typical effective dose 0.001 mSv, similar to under a day of natural background radiation (about 3 mSv a year).
Fundus photography (retinal screening)
A Fundus photography (retinal screening) is a diagnostic procedure test of the eye. It shows pictures of the retina for diabetic or hypertensive changes. No ionising radiation when done without X-ray guidance.
Gallium or infection scan
A Gallium or infection scan is a nuclear medicine test of the whole body. It shows hidden infection or inflammation. Typical effective dose 5 to 15 mSv, similar to about 2 to 5 years of natural background radiation (about 3 mSv a year).
Gastric emptying study
A Gastric emptying study is a nuclear medicine test of the stomach. It shows how fast food leaves the stomach. Typical effective dose 0.3 to 0.5 mSv, similar to about 1 to 2 months of natural background radiation (about 3 mSv a year).
Hand and wrist X-ray
A Hand and wrist X-ray is a x-ray test of the hand and wrist. It shows fractures, arthritis, bone age in children. Typical effective dose 0.001 mSv, similar to under a day of natural background radiation (about 3 mSv a year).
Hepatic Doppler ultrasound
A Hepatic Doppler ultrasound is a ultrasound test of the liver vessels. It shows blood flow in liver veins and arteries; clots and portal hypertension. No ionising radiation (sound waves).
Hernia ultrasound
A Hernia ultrasound is a ultrasound test of the groin and abdominal wall. It shows hernias and their contents. No ionising radiation (sound waves).
HIDA scan (hepatobiliary scintigraphy)
A HIDA scan (hepatobiliary scintigraphy) is a nuclear medicine test of the gallbladder and bile ducts. It shows gallbladder function and bile flow. Typical effective dose 2 to 4 mSv, similar to about 1 year of natural background radiation (about 3 mSv a year).
High-resolution CT of the chest (HRCT)
A High-resolution CT of the chest (HRCT) is a ct test of the chest. It shows fine lung detail: interstitial lung disease, bronchiectasis, COVID-19 changes. Typical effective dose 4 to 7 mSv, similar to about 1.5 to 2 years of natural background radiation (about 3 mSv a year).
Hip MRI
A Hip MRI is a mri test of the hip. It shows avascular necrosis, hidden fractures, labral tears. No ionising radiation (magnetic field and radio waves).
Hip X-ray in children
A Hip X-ray in children is a x-ray test of the hips. It shows slipped growth plate, Perthes disease, hip infection signs. Typical effective dose 0.1 to 0.3 mSv, similar to about 2 to 5 weeks of natural background radiation (about 3 mSv a year).
Holter monitoring (24 to 48 hour ECG)
A Holter monitoring (24 to 48 hour ECG) is a diagnostic procedure test of the heart. It shows heart rhythm over one or more days. No ionising radiation when done without X-ray guidance.
Hysterosalpingography (HSG)
A Hysterosalpingography (HSG) is a x-ray (fluoroscopy) test of the uterus and fallopian tubes. It shows shape of the uterus and whether tubes are open. Typical effective dose 1 to 3 mSv, similar to about 4 months to 1 year of natural background radiation (about 3 mSv a year).
Image-guided abscess or fluid drainage
A Image-guided abscess or fluid drainage is a interventional test of the variable. It shows drains an abscess, fluid in the chest or belly under ultrasound or CT. No ionising radiation when done without X-ray guidance.
Infant hip ultrasound
A Infant hip ultrasound is a ultrasound test of the hips (infant). It shows hip development (DDH). No ionising radiation (sound waves).
Intravenous urogram (IVU)
A Intravenous urogram (IVU) is a fluoroscopy test of the urinary tract. It shows kidney outline and drainage; mostly replaced by CT. Typical effective dose 2 to 3 mSv, similar to about 8 months to 1 year of natural background radiation (about 3 mSv a year).
IVC filter placement
A IVC filter placement is a interventional test of the large vein. It shows a filter to catch leg clots before they reach the lungs. Typical effective dose 2 to 5 mSv, similar to about 8 months to 1.5 years of natural background radiation (about 3 mSv a year).
Kidney, ureter and bladder ultrasound (USG KUB)
A Kidney, ureter and bladder ultrasound (USG KUB) is a ultrasound test of the kidneys and bladder. It shows kidney size, stones, swelling (hydronephrosis), bladder emptying, prostate size. No ionising radiation (sound waves).
Knee X-ray
A Knee X-ray is a x-ray test of the knee. It shows joint space narrowing (osteoarthritis), fractures, effusion. Typical effective dose 0.005 mSv, similar to under a day of natural background radiation (about 3 mSv a year).
KUB X-ray
A KUB X-ray is a x-ray test of the kidneys, ureters and bladder. It shows some kidney and ureter stones. Typical effective dose 0.7 mSv, similar to about 3 months of natural background radiation (about 3 mSv a year).
Limb X-ray (arm, leg, joint)
A Limb X-ray (arm, leg, joint) is a x-ray test of the limbs and joints. It shows fractures, dislocations, arthritis, bone infection. Typical effective dose 0.001 to 0.01 mSv, similar to less than a day of natural background radiation (about 3 mSv a year).
Liver elastography (FibroScan)
A Liver elastography (FibroScan) is a ultrasound test of the liver. It shows liver stiffness (scarring) and fat. No ionising radiation (sound waves).
Low-dose CT lung cancer screening
A Low-dose CT lung cancer screening is a ct test of the chest. It shows early lung cancers in heavy smokers; reported with Lung-RADS. Typical effective dose about 1.5 mSv, similar to about 6 months of natural background radiation (about 3 mSv a year).
Lower back (lumbar spine) X-ray
A Lower back (lumbar spine) X-ray is a x-ray test of the lower back. It shows alignment, degeneration, fractures, slipped vertebra. Typical effective dose 1 to 1.5 mSv, similar to about 4 to 6 months of natural background radiation (about 3 mSv a year).
Lower leg (tibia and fibula) X-ray
A Lower leg (tibia and fibula) X-ray is a x-ray test of the lower leg. It shows fractures. Typical effective dose 0.001 mSv, similar to under a day of natural background radiation (about 3 mSv a year).
Lumbar puncture (spinal tap)
A Lumbar puncture (spinal tap) is a diagnostic procedure test of the spine (csf). It shows collects spinal fluid to test for infection, bleeding or inflammation. No ionising radiation when done without X-ray guidance.
Lymphoscintigraphy / sentinel node scan
A Lymphoscintigraphy / sentinel node scan is a nuclear medicine test of the lymph nodes. It shows lymph drainage and the first node a cancer may spread to. Typical effective dose 0.2 to 1 mSv, similar to about 1 to 4 months of natural background radiation (about 3 mSv a year).
Mammography
A Mammography is a x-ray test of the breast. It shows breast tissue, lumps and calcifications, reported with ACR BI-RADS. Typical effective dose about 0.4 mSv, similar to about 7 weeks of natural background radiation (about 3 mSv a year).
Mastoid X-ray
A Mastoid X-ray is a x-ray test of the ear bone. It shows mastoid air cells (CT is more accurate). Typical effective dose 0.02 to 0.1 mSv, similar to a few days of natural background radiation (about 3 mSv a year).
Micturating cystourethrogram (MCU / VCUG)
A Micturating cystourethrogram (MCU / VCUG) is a fluoroscopy test of the bladder and urethra. It shows urine flowing back to the kidneys (reflux), urethral problems. Typical effective dose 0.5 to 1.5 mSv, similar to about 2 to 6 months of natural background radiation (about 3 mSv a year).
MR angiography (MRA)
A MR angiography (MRA) is a mri test of the blood vessels. It shows blood vessels without X-rays. No ionising radiation (magnetic field and radio waves).
MR enterography
A MR enterography is a mri test of the small bowel. It shows small bowel inflammation without radiation. No ionising radiation (magnetic field and radio waves).
MR spectroscopy of the brain
A MR spectroscopy of the brain is a mri test of the head. It shows chemical make-up of a brain lesion. No ionising radiation (magnetic field and radio waves).
MRCP (MR cholangiopancreatography)
A MRCP (MR cholangiopancreatography) is a mri test of the bile ducts and pancreas. It shows stones or narrowing in the bile ducts, pancreatic duct. No ionising radiation (magnetic field and radio waves).
MRI fistulogram (perianal MRI)
A MRI fistulogram (perianal MRI) is a mri test of the anal region. It shows anal fistula tracks and abscesses. No ionising radiation (magnetic field and radio waves).
MRI for liver iron (T2*)
A MRI for liver iron (T2*) is a mri test of the liver and heart. It shows iron overload in the liver and heart. No ionising radiation (magnetic field and radio waves).
MRI of the brain
A MRI of the brain is a mri test of the head. It shows brain tissue in fine detail: stroke, tumours, MS, infections. No ionising radiation (magnetic field and radio waves).
MRI of the brain
A detailed scan using magnets, with no X-ray radiation.
MRI of the knee
A MRI of the knee is a mri test of the knee. It shows ligaments, menisci, cartilage. No ionising radiation (magnetic field and radio waves).
MRI of the spine
A MRI of the spine is a mri test of the spine. It shows discs, nerves and spinal cord: slipped disc, compression, infection. No ionising radiation (magnetic field and radio waves).
MUGA scan
A MUGA scan is a nuclear medicine test of the heart. It shows precise heart pumping fraction. Typical effective dose 5 to 8 mSv, similar to about 2 to 3 years of natural background radiation (about 3 mSv a year).
Musculoskeletal ultrasound
A Musculoskeletal ultrasound is a ultrasound test of the muscles and tendons. It shows tendon tears, bursitis, joint fluid. No ionising radiation (sound waves).
Myocardial perfusion imaging (nuclear stress test)
A Myocardial perfusion imaging (nuclear stress test) is a nuclear medicine test of the heart. It shows blood supply to the heart muscle at rest and under stress. Typical effective dose 9 to 12 mSv, similar to about 3 to 4 years of natural background radiation (about 3 mSv a year).
Neck (cervical spine) X-ray
A Neck (cervical spine) X-ray is a x-ray test of the neck. It shows alignment, spondylosis, fractures. Typical effective dose 0.1 to 0.2 mSv, similar to about 2 to 3 weeks of natural background radiation (about 3 mSv a year).
Neck MRI (soft tissue)
A Neck MRI (soft tissue) is a mri test of the neck. It shows throat and salivary gland masses. No ionising radiation (magnetic field and radio waves).
Neck ultrasound (lymph nodes, salivary glands)
A Neck ultrasound (lymph nodes, salivary glands) is a ultrasound test of the neck. It shows lymph nodes, salivary glands, lumps. No ionising radiation (sound waves).
Nerve conduction study and EMG
A Nerve conduction study and EMG is a diagnostic procedure test of the nerves and muscles. It shows how well nerves carry signals and muscles respond. No ionising radiation when done without X-ray guidance.
Nuchal translucency (NT) scan
A Nuchal translucency (NT) scan is a ultrasound test of the pregnancy. It shows fluid at the back of the baby's neck at 11 to 14 weeks, used in screening for chromosomal conditions. No ionising radiation (sound waves).
Obstetric Doppler
A Obstetric Doppler is a ultrasound test of the pregnancy. It shows blood flow to the baby and placenta. No ionising radiation (sound waves).
Obstetric ultrasound (pregnancy scan)
A Obstetric ultrasound (pregnancy scan) is a ultrasound test of the pregnancy. It shows baby's age, growth, heartbeat, position, placenta and amniotic fluid. No ionising radiation (sound waves).
Optical coherence tomography of the eye (OCT)
A Optical coherence tomography of the eye (OCT) is a diagnostic procedure test of the eye. It shows retina layers: macular swelling, glaucoma damage. No ionising radiation when done without X-ray guidance.
Orbit MRI
A Orbit MRI is a mri test of the eyes and optic nerves. It shows optic nerve, eye muscles, masses. No ionising radiation (magnetic field and radio waves).
Pap smear and VIA (cervical screening)
A Pap smear and VIA (cervical screening) is a diagnostic procedure test of the cervix. It shows cell changes in the cervix (or visual inspection with acetic acid). No ionising radiation when done without X-ray guidance.
Parathyroid (sestamibi) scan
A Parathyroid (sestamibi) scan is a nuclear medicine test of the neck. It shows overactive parathyroid glands. Typical effective dose 5 to 7 mSv, similar to about 2 years of natural background radiation (about 3 mSv a year).
Pelvic MRI
A Pelvic MRI is a mri test of the pelvis. It shows uterus, ovaries, rectum; fibroids, endometriosis, cancer staging. No ionising radiation (magnetic field and radio waves).
Pelvic ultrasound
A Pelvic ultrasound is a ultrasound test of the pelvis. It shows uterus, ovaries, bladder; fibroids, cysts, polycystic ovaries. No ionising radiation (sound waves).
Pelvis and hip X-ray
A Pelvis and hip X-ray is a x-ray test of the pelvis and hips. It shows fractures, hip arthritis, bone changes. Typical effective dose 0.6 mSv, similar to about 2 months of natural background radiation (about 3 mSv a year).
Percutaneous nephrostomy (PCN)
A Percutaneous nephrostomy (PCN) is a interventional test of the kidney. It shows a tube placed into a blocked kidney to drain urine. Typical effective dose 1 to 3 mSv, similar to about 4 months to 1 year of natural background radiation (about 3 mSv a year).
Percutaneous transhepatic biliary drainage (PTBD)
A Percutaneous transhepatic biliary drainage (PTBD) is a interventional test of the bile ducts. It shows a tube to drain blocked bile ducts. Typical effective dose 5 to 10 mSv, similar to about 2 to 3 years of natural background radiation (about 3 mSv a year).
PET-CT scan
A PET-CT scan is a nuclear medicine test of the whole body. It shows active tissue such as cancer, infection or inflammation. Typical effective dose 10 to 25 mSv, similar to about 3 to 8 years of natural background radiation (about 3 mSv a year).
Pituitary MRI
A Pituitary MRI is a mri test of the head. It shows pituitary tumours. No ionising radiation (magnetic field and radio waves).
Portal venous Doppler
A Portal venous Doppler is a ultrasound test of the liver vessels. It shows portal vein flow and clots, signs of portal hypertension. No ionising radiation (sound waves).
Pregnancy ultrasound
A sound-wave scan to check the baby and pregnancy.
Prostate MRI (multiparametric, mpMRI)
A Prostate MRI (multiparametric, mpMRI) is a mri test of the prostate. It shows suspicious areas in the prostate, reported with PI-RADS. No ionising radiation (magnetic field and radio waves).
Pulmonary function test / spirometry
A Pulmonary function test / spirometry is a diagnostic procedure test of the lungs. It shows how much and how fast you can breathe out; reversibility after an inhaler. No ionising radiation when done without X-ray guidance.
Radioactive iodine therapy (I-131)
A Radioactive iodine therapy (I-131) is a nuclear medicine test of the thyroid. It shows a treatment, not a scan: destroys overactive thyroid tissue or remaining thyroid cancer. Typical effective dose therapeutic dose; radiation safety advice is given mSv, similar to not comparable (treatment) of natural background radiation (about 3 mSv a year).
Radiofrequency or microwave ablation
A Radiofrequency or microwave ablation is a interventional test of the liver, kidney, thyroid. It shows destroys small tumours with heat through a needle. Typical effective dose 2 to 10 (CT-guided) or none (ultrasound) mSv, similar to up to about 3 years of natural background radiation (about 3 mSv a year).
Renal artery Doppler
A Renal artery Doppler is a ultrasound test of the kidney arteries. It shows narrowing of kidney arteries. No ionising radiation (sound waves).
Renal MR angiography
A Renal MR angiography is a mri test of the kidney arteries. It shows narrowed kidney arteries. No ionising radiation (magnetic field and radio waves).
Renal scan in children (MAG3)
A Renal scan in children (MAG3) is a nuclear medicine test of the kidneys. It shows kidney drainage and function in children. Typical effective dose 0.3 to 1 mSv, similar to about 1 to 4 months of natural background radiation (about 3 mSv a year).
Retrograde urethrogram (RGU)
A Retrograde urethrogram (RGU) is a fluoroscopy test of the urethra. It shows urethral narrowing or injury. Typical effective dose 0.5 to 1 mSv, similar to about 2 to 4 months of natural background radiation (about 3 mSv a year).
Rib X-ray
A Rib X-ray is a x-ray test of the ribs. It shows rib fractures, sometimes a collapsed lung. Typical effective dose 0.1 mSv, similar to about 10 days of natural background radiation (about 3 mSv a year).
Sacroiliac joint MRI
A Sacroiliac joint MRI is a mri test of the pelvis. It shows early inflammation in spondyloarthritis. No ionising radiation (magnetic field and radio waves).
Sacroiliac joint X-ray
A Sacroiliac joint X-ray is a x-ray test of the pelvis. It shows inflammation of the sacroiliac joints. Typical effective dose 0.3 to 0.7 mSv, similar to about 1 to 3 months of natural background radiation (about 3 mSv a year).
Salivary gland scan
A Salivary gland scan is a nuclear medicine test of the salivary glands. It shows salivary gland function. Typical effective dose 1 to 2 mSv, similar to about 4 to 8 months of natural background radiation (about 3 mSv a year).
Scoliosis (whole spine) X-ray
A Scoliosis (whole spine) X-ray is a x-ray test of the spine. It shows spine curvature measurement. Typical effective dose 0.2 to 1 mSv, similar to about 1 to 4 months of natural background radiation (about 3 mSv a year).
Scrotal ultrasound
A Scrotal ultrasound is a ultrasound test of the scrotum. It shows testes, epididymis, hydrocele, varicocele, torsion. No ionising radiation (sound waves).
Shoulder MRI
A Shoulder MRI is a mri test of the shoulder. It shows rotator cuff tears, labrum, cartilage. No ionising radiation (magnetic field and radio waves).
Shoulder X-ray
A Shoulder X-ray is a x-ray test of the shoulder. It shows fractures, dislocation, arthritis, calcific tendinitis. Typical effective dose 0.01 mSv, similar to about 1 day of natural background radiation (about 3 mSv a year).
Sialogram
A Sialogram is a fluoroscopy test of the salivary ducts. It shows salivary duct stones or narrowing. Typical effective dose 0.1 to 0.5 mSv, similar to about 2 weeks to 2 months of natural background radiation (about 3 mSv a year).
Sinus X-ray (PNS view)
A Sinus X-ray (PNS view) is a x-ray test of the face. It shows air-fluid levels and thickening in the sinuses. Typical effective dose 0.02 to 0.1 mSv, similar to a few days of natural background radiation (about 3 mSv a year).
Skull X-ray
A Skull X-ray is a x-ray test of the head. It shows skull bones; largely replaced by CT for head injury. Typical effective dose 0.1 mSv, similar to about 2 weeks of natural background radiation (about 3 mSv a year).
Sleep study (polysomnography)
A Sleep study (polysomnography) is a diagnostic procedure test of the sleep. It shows breathing, oxygen and brain activity during sleep. No ionising radiation when done without X-ray guidance.
Soft-tissue neck X-ray
A Soft-tissue neck X-ray is a x-ray test of the neck. It shows airway swelling, swallowed bones, adenoids in children. Typical effective dose 0.01 to 0.1 mSv, similar to about 1 to 10 days of natural background radiation (about 3 mSv a year).
Soft-tissue ultrasound
A Soft-tissue ultrasound is a ultrasound test of the skin and soft tissue. It shows lumps, abscesses, hernias, foreign bodies. No ionising radiation (sound waves).
Somatostatin receptor scan (Ga-68 DOTATATE PET)
A Somatostatin receptor scan (Ga-68 DOTATATE PET) is a nuclear medicine test of the whole body. It shows neuroendocrine tumours. Typical effective dose 5 to 15 mSv, similar to about 2 to 5 years of natural background radiation (about 3 mSv a year).
Spine X-ray
A Spine X-ray is a x-ray test of the spine. It shows bone alignment, fractures, degeneration. Typical effective dose 0.2 to 1.5 mSv, similar to about 1 to 6 months of natural background radiation (about 3 mSv a year).
Stress echocardiogram
A Stress echocardiogram is a ultrasound test of the heart. It shows heart muscle movement during exercise or medicine-induced stress. No ionising radiation (sound waves).
TACE (transarterial chemoembolisation)
A TACE (transarterial chemoembolisation) is a interventional test of the liver. It shows delivers chemotherapy and blocks a liver tumour's blood supply. Typical effective dose 10 to 30 mSv, similar to about 3 to 10 years of natural background radiation (about 3 mSv a year).
Thigh (femur) X-ray
A Thigh (femur) X-ray is a x-ray test of the thigh. It shows fractures and bone lesions. Typical effective dose 0.01 to 0.02 mSv, similar to about 1 to 3 days of natural background radiation (about 3 mSv a year).
Third-trimester growth scan
A Third-trimester growth scan is a ultrasound test of the pregnancy. It shows baby's growth, position, fluid and placenta. No ionising radiation (sound waves).
Thyroid scan (Tc-99m or iodine uptake)
A Thyroid scan (Tc-99m or iodine uptake) is a nuclear medicine test of the thyroid. It shows how active the thyroid or a nodule is. Typical effective dose 1 to 2 mSv, similar to about 4 to 8 months of natural background radiation (about 3 mSv a year).
Thyroid ultrasound
A Thyroid ultrasound is a ultrasound test of the neck. It shows thyroid size and nodules, scored with ACR TI-RADS. No ionising radiation (sound waves).
TMJ MRI
A TMJ MRI is a mri test of the jaw joint. It shows jaw joint disc position. No ionising radiation (magnetic field and radio waves).
Transcranial Doppler
A Transcranial Doppler is a ultrasound test of the brain vessels. It shows blood flow speed in brain arteries. No ionising radiation (sound waves).
Transoesophageal echocardiogram (TEE/TOE)
A Transoesophageal echocardiogram (TEE/TOE) is a ultrasound test of the heart. It shows detailed heart valves and chambers, clots in the heart. No ionising radiation (sound waves).
Transrectal prostate ultrasound (TRUS)
A Transrectal prostate ultrasound (TRUS) is a ultrasound test of the prostate. It shows prostate size and guides biopsy. No ionising radiation (sound waves).
Transvaginal ultrasound (TVS)
A Transvaginal ultrasound (TVS) is a ultrasound test of the pelvis. It shows detailed uterus, lining and ovaries; early pregnancy. No ionising radiation (sound waves).
Treadmill test (TMT, exercise ECG)
A Treadmill test (TMT, exercise ECG) is a diagnostic procedure test of the heart. It shows heart rhythm and ECG changes during exercise. No ionising radiation when done without X-ray guidance.
Tympanometry
A Tympanometry is a diagnostic procedure test of the middle ear. It shows movement of the eardrum and middle-ear fluid. No ionising radiation when done without X-ray guidance.
Ultrasound abdomen and pelvis (USG)
A Ultrasound abdomen and pelvis (USG) is a ultrasound test of the abdomen and pelvis. It shows liver, gallbladder, kidneys, bladder, uterus, ovaries, prostate; stones, fatty liver, fluid, masses. No ionising radiation (sound waves).
Ultrasound for appendicitis
A Ultrasound for appendicitis is a ultrasound test of the right lower abdomen. It shows an inflamed appendix, especially in children and pregnancy. No ionising radiation (sound waves).
Ultrasound-guided core biopsy
A Ultrasound-guided core biopsy is a interventional test of the variable. It shows takes a small tissue core for diagnosis. No ionising radiation when done without X-ray guidance.
Ultrasound-guided FNAC
A Ultrasound-guided FNAC is a interventional test of the variable. It shows takes cells from a lump with a thin needle under ultrasound for microscopy. No ionising radiation when done without X-ray guidance.
Ultrasound-guided joint or nerve injection
A Ultrasound-guided joint or nerve injection is a interventional test of the joints and nerves. It shows places a needle accurately for pain relief injections. No ionising radiation when done without X-ray guidance.
Upper abdomen ultrasound (liver, gallbladder, pancreas)
A Upper abdomen ultrasound (liver, gallbladder, pancreas) is a ultrasound test of the upper abdomen. It shows gallstones, fatty liver, liver size and texture, bile duct widening. No ionising radiation (sound waves).
Upper back (thoracic spine) X-ray
A Upper back (thoracic spine) X-ray is a x-ray test of the upper back. It shows compression fractures, curvature. Typical effective dose 0.7 to 1 mSv, similar to about 3 to 4 months of natural background radiation (about 3 mSv a year).
Upper GI endoscopy (OGD)
A Upper GI endoscopy (OGD) is a diagnostic procedure test of the oesophagus, stomach and duodenum. It shows ulcers, inflammation, bleeding, varices; biopsies and H. pylori tests. No ionising radiation when done without X-ray guidance.
Urodynamic study
A Urodynamic study is a diagnostic procedure test of the bladder. It shows bladder pressure and urine flow. No ionising radiation when done without X-ray guidance.
Uterine artery embolisation
A Uterine artery embolisation is a interventional test of the uterus. It shows blocks blood supply to fibroids. Typical effective dose 10 to 20 mSv, similar to about 3 to 7 years of natural background radiation (about 3 mSv a year).
Venous Doppler of the legs
A Venous Doppler of the legs is a ultrasound test of the leg veins. It shows clots (DVT), varicose vein reflux. No ionising radiation (sound waves).
Ventilation-perfusion (V/Q) scan
A Ventilation-perfusion (V/Q) scan is a nuclear medicine test of the lungs. It shows mismatched air and blood flow suggesting pulmonary embolism. Typical effective dose 1 to 2 mSv, similar to about 4 to 8 months of natural background radiation (about 3 mSv a year).
Vertebral fracture assessment (DEXA VFA)
A Vertebral fracture assessment (DEXA VFA) is a dexa test of the spine. It shows hidden spine fractures during a bone density scan. Typical effective dose about 0.002 to 0.04 mSv, similar to under a week of natural background radiation (about 3 mSv a year).
Vertebroplasty / kyphoplasty
A Vertebroplasty / kyphoplasty is a interventional test of the spine. It shows cement injected into a painful collapsed vertebra. Typical effective dose 2 to 10 mSv, similar to about 8 months to 3 years of natural background radiation (about 3 mSv a year).
Visual and auditory evoked potentials
A Visual and auditory evoked potentials is a diagnostic procedure test of the nerves to eyes and ears. It shows how fast signals travel along vision and hearing pathways. No ionising radiation when done without X-ray guidance.
Whole-body iodine scan (thyroid cancer)
A Whole-body iodine scan (thyroid cancer) is a nuclear medicine test of the whole body. It shows remaining thyroid tissue or spread after thyroid cancer surgery. Typical effective dose 1 to 5 mSv, similar to about 4 months to 2 years of natural background radiation (about 3 mSv a year).
Whole-body trauma CT
A Whole-body trauma CT is a ct test of the whole body. It shows bleeding, organ injury, fractures after major trauma. Typical effective dose 10 to 20 mSv, similar to about 3 to 7 years of natural background radiation (about 3 mSv a year).
Whole-spine MRI
A Whole-spine MRI is a mri test of the spine. It shows cord compression, infection (including spinal TB), tumours. No ionising radiation (magnetic field and radio waves).
Wrist MRI
A Wrist MRI is a mri test of the wrist. It shows hidden scaphoid fracture, ligaments. No ionising radiation (magnetic field and radio waves).
Emergency — call102